Sunday, 31 October 2010

Stainless Steel in Architecture

Posted on 22:20 by Unknown

Stainless Steel has immense applications in Architecture. It has applications in Roofing, Facade, panels both in interiors and exteriors, etc.

Stainless steel structures provide both strength as well as maintenance free long life. In roofing applications, it helps in reducing the airconditioning loads due to reduction in Heat transfer inside the building.
Read More
Posted in | No comments

Tuesday, 12 October 2010

Comparison of Various Materials in Plumbing

Posted on 20:58 by Unknown




This post compares various materials used in Plumbing.

Read More
Posted in | No comments

Monday, 11 October 2010

Piping Manual for SS in Building

Posted on 01:09 by Unknown
The Stainless Steel Piping manual can be downloaded from this link. This is a comprehensive Technical Manual and is extremely useful for all the designers and Plumbing Consultants.

http://www.nickelinstitute.org/index.cfm/ci_id/15786/la_id/1/ci_doc_id/3096/search_keyword/12008/method/2.html

Alternate Website which doesn't require any login is:
http://cid-5dd969b2d3b67058.office.live.com/self.aspx/SS%20Plumbing/12008%20-%20Piping%20Manual%20For%20Buildings-%20Japan.pdf

Read More
Posted in | No comments

Sunday, 22 August 2010

How stainless steel water pipes cut costs and reduce waste

Posted on 23:52 by Unknown


Lightweight stainless steel construction permits easy and simple lifting of pipe into place, 5 metres off the floor. (Top) Two men easily connect 6-metre lengths of pipe using relatively simple equipment. In addition, there is no need to clean the ends of the grooved pipe. Stainless steel sub-assemblies and pre-fabricated and curved, mitered sections avoid the need for complex fittings and connections. (Below) Smaller diameter copper pipes deliver water to various washrooms and concession stands. Stainless steel piping has been used in Detroit's Veterans Administration Hospital since 1993. Incoming potable water is pumped through 500-mm-diameter, schedule 10 pipe, made of S30403 stainless steel. The lines are insulated to prevent condensation.








Nickel magazine, Jun. 01 -- It might take a few years, but stainless steel pipe could become as common in North American domestic water systems as it is currently in Japan or Germany. Penetration of stainless into the North American market is off to a good start with the completion of one such application at a high-profile venue in Detroit, Michigan.

The venue is a new, US$300-million stadium called Ford Field, which is being built by the Ford family, owners of the hometown "Lions" of the National Football League.

A total of 600 metres of S30403 stainless steel pipe -- 300 millimetres (mm) in diameter and with a wall thickness of 4.57 mm -- has been suspended from the concrete ceiling around the entire stadium perimeter. The grooved ends of the pipe were connected using mechanical couplings and smaller-diameter copper pipes deliver potable water from the main stainless pipe to various washrooms and concession stands around the stadium.

The pipe was manufactured by Felker Brothers and distributed by Bertsch, a USFlow Company.

W. J. O'Neil Company (WJO), a mechanical contractor, won a US$25-million contract to fabricate and install all the plumbing, waste and heating systems for the stadium, which is scheduled to open in time for the 2002 football season.

The decision to use stainless was based almost entirely on economics, according to Robert Gazda, General Manager of WJO. Although material costs were some 20% higher than if galvanized carbon steel pipe had been used, significant savings in fabrication and installation were realized as a result of opting for stainless.

The excellent corrosion resistance of stainless steel allowed thinner wall thicknesses to be used than other competitive materials, resulting in several factors that helped to reduce installation costs. Considerable weight savings per metre of pipe were realized, as well a greater ease in the handling, lifting and installation of long sections of pipe. WJO was able to install sections up to six metres long.

For the operators of the sports facility, the main advantage of stainless steel is that the lines need to be flushed only occasionally, whereas, if galvanized pipe had been used, more frequent flushing would have been required to remove the zinc corrosion products (zinc carbonate and sulphate) that inevitably develop. This means less labour will be required for flushing and less water will be wasted, an important consideration in a city where water supply costs have gone up by 30% in the past year.

Since stainless has never been used in a domestic water system in Michigan, no state engineering standard existed prior to this installation. It is not surprising, then that the City of Detroit put up some resistance. However, recent NiDI Water Workshop presentations in the region in the fall of 2000, and experience gained from the use of stainless steel cold water piping at the Veterans Hospital in Detroit, where 500-mm-diameter stainless steel pipe was installed in 1993 under Federal standards, helped convince city officials to accept the use of stainless steel at Ford Field.

Reflecting on WJO's success in developing an economical way to fabricate and install the stainless pipe, Gazda says, "I'm sure there will be a whole lot more jobs after this one."

Read More
Posted in | No comments

Monday, 2 August 2010

5 years test result of SS vs other pipes

Posted on 23:58 by Unknown

Stainless steel and other pipes used in city water supply were subjected to five year underground installation tests in 25 cities of Japan. These 5 year test results in Japan have proved that
  • stainless steel piping (SS 304 or 316) have not undergone any corrosion
  • the carbon steel (avg - 0.019 mm/yr) and lead pipes (0.002mm/yr) have very high corrosion rates with a maximum corrosion rate of 5-6 times these average rates.
  • The cast Copper pipes and fittings have undergone frequent corrosion.
Generally speaking, SS 304 pipes didn't develop any degradation at site except slight discoloration and exhibited excellent corrosion resistance. SS 316 pipes were free from even the discoloration.

Read More
Posted in carbon steel, Comparison Stainless steel, Copper | No comments

Wednesday, 7 July 2010

Water Pipe Material in Hospitals - NHS Scotland

Posted on 05:03 by Unknown
An interesting extract

"Scottish Health Technical Memorandum 04-01:"
The control of Legionella, hygiene, ‘safe’ hot water, cold water and drinking water systems

11.8 The materials generally used for the conveyance of water in healthcare premises are stainless steel or plastics. Copper is only used in exceptional circumstances such as, an extension to existing premises with short life expectancy, or very small stand alone premises. Where this is specified, only lead-free solders should be used.

11.9 Substances leached from materials of construction of pipes, cisterns or other water fittings in contact with water must not adversely affect the quality of water stored or drawn for domestic or food production purposes (Water Byelaws (Scotland) 2000).

11.10 Direct gas-fired water heaters are particularly prone to corrosion and scale formation, and the inside of these heaters should be provided with suitable linings to limit these effects. Steel pipes and fittings

11.12 The character of water in Scotland is such that steel, whether galvanised or not, should not be used at all for domestic hot and cold water installations. Any existing premises with such pipework shall have this scheduled for early replacement.

Stainless steel
11.13 Stainless steel is being increasingly used in hot and cold water service systems. Reference should be made to SHTN 2: ‘Domestic hot and cold water systems for Scottish health care premises’.

Copper pipes and copper/copper alloy fittings
11.14 As described previously, careful consideration will be required if copper pipework and fittings are to be specified for healthcare premises in Scotland. Where this is considered to be acceptable either due to the size of the project or the anticipated lifespan of the facility, the following will apply.
11.15 Copper in general is resistant to corrosion. Unless resistant to dezincification, brass fittings must not be used where water conveyed is capable of dissolving undue amounts of zinc from the fitting. External protection from corrosion for buried pipework may be obtained by using copper tube with a factory-applied polythene sheath.

http://www.hfs.scot.nhs.uk/publications/1265986939-v24%2520SHTM%252004-01%2520Part%2520A.pdf
Read More
Posted in | No comments

Sunday, 4 July 2010

Effect Of Galvanized Pipe Upon Water

Posted on 21:42 by Unknown
Zinc coatings on the surface of galvanized iron pipe are attacked and dissolved by some waters almost as energetically as is lead pipe. Zinc is also dissolved to a considerable extent from brass pipes. At Cwmfelin,* in Wales, galvanized iron pipe that conducts water from a spring to the town, a distance of one-half mile, was found to change the character of the water as shown by the following analysis:
At Spring At Delivery
Nitrogen as nitrates..... .8 114
Total residue .... . . 154.3 270
Zinc carbonate .... ... none 91.6

Effect Of Metals On Health
Kind of Pipe Action of Water Effect upon People
Lead pipe..... Dissolves lead Dangerous
Tin or tin lined lead No effect No effect
Galvanized iron .... Dissolves zinc Injurious
Tin lined iron..... No effect No effect
Brass pipe .... Slightly dissolves Objectionable
copper and zinc
Plain iron .... Rusts and dissolves Objectionable
Aluminium No effect No effect
Nickel..... No effect No effect
Benedict nickel .... No effect No effect

The action of water upon galvanized iron pipes is almost as energetic as upon lead pipes, and under suitable conditions will dissolve equal amounts of metal from each. However, the effect of the zinc upon the health is not dangerous but only injurious, because zinc is not a cumulative poison, and so long as the initial dose is not sufficient to cause illness or death, the effect is soon thrown off without apparent injury. Lead, on the contrary, even when taken in small doses, remains in the system until sufficient poison accumulates to cause serious illness or death, or if the initial dose is of sufficient strength the effect may be immediately fatal.

http://chestofbooks.com/home-improvement/construction/plumbing/Principle-Practice/Effect-Of-Galvanized-Pipe-Upon-Water.html

Read More
Posted in | No comments
Newer Posts Older Posts Home
Subscribe to: Posts (Atom)

Popular Posts

  • Case Study in Stainless Steel Plumbing System
    Various controlled studies have served to give confidence in the use of stainless steel plumbing systems. Two examples are: 1) A 10 year Ja...
  • 5 years test result of SS vs other pipes
    Stainless steel and other pipes used in city water supply were subjected to five year underground installation tests in 25 cities of Japan. ...
  • Comparison of Various Materials in Plumbing
    This post compares various materials used in Plumbing.
  • Urban water distribution systems are evolving toward stainless steel
    Nickel Magazine, March 2005 -- The piping systems that deliver potable water and fire-fighting capabilities in tall buildings have unique r...
  • Grooved Piping System in SS
    The new and latest technology to enter India is the Grooved pipe joining system which is used primarily in bigger size pipe for applications...
  • Stainless Steel Piping Survives Earthquake Shocks
    Earthquake-resistance tests have shown that stainless steel piping systems (joined by mechanical couplings) exhibit good air tightness and d...
  • Benefits of Using Stainless Steel in Water Supply
    Material Benefits • Stainless steel has a very low general corrosion rate in water and no corrosion allowance is required. • It can withstan...
  • LEED certification - Stainless Steel
    I would like to initiate a discussion on how Stainless steel helps in getting points for LEED certification. Stainless Steel properties like...
  • SS Pipe - Press Fit Design Joining Video
    This video shows the joining process for Stainless Steel plumbing Systems. The innovative press fit design saves both time as well as labor ...
  • Effect Of Galvanized Pipe Upon Water
    Zinc coatings on the surface of galvanized iron pipe are attacked and dissolved by some waters almost as energetically as is lead pipe. Zinc...

Categories

  • 304
  • building life increase
  • carbon steel
  • Case study
  • certification
  • Comparison Stainless steel
  • Copper
  • Earthquake shocks
  • Goel
  • High rise
  • India
  • J-Press
  • LEED
  • Lifecycle cost
  • Piping
  • Plumbing
  • Pravin
  • Press Fit Design
  • pressfit design
  • SS Plumbing
  • Stainless
  • stainless plumbing
  • Stainless Steel
  • Steel
  • Water distribution
  • Water pipelines

Blog Archive

  • ▼  2013 (2)
    • ▼  April (2)
      • Water Pipes Evolve to Stainless Steel
      • SS Piping in Water Distribution
  • ►  2012 (2)
    • ►  September (2)
  • ►  2011 (5)
    • ►  November (1)
    • ►  September (2)
    • ►  June (1)
    • ►  January (1)
  • ►  2010 (19)
    • ►  October (3)
    • ►  August (2)
    • ►  July (4)
    • ►  June (10)
Powered by Blogger.

About Me

Unknown
View my complete profile